Microwave Digestion System ,Total Organic Carbon Analyzer (TOC)
LMDS600
Microwave Digestion System
# 7 inch color Touch Screen Display.
# Standard 6 vessels
# Vertical design for even distribution of
microwave.
# Real-time monitoring for both temperature
and pressure of each vessel.
# Imported vessel material for both sample
vessel and protection vessel highly ensures
safety.
# 7 inch color Touch Screen Display.
# Standard 6 vessels
# Vertical design for even distribution of
microwave.
# Real-time monitoring for both temperature
and pressure of each vessel.
# Imported vessel material for both sample
vessel and protection vessel highly ensures
safety.
LTOC1000
Total Organic Carbon Analyzer (TOC)
# Detection range - 0.001 - 1.500mg/l (ppm).
# Equipped with Conductivity detector.
to quantify TOC Concentration.
# 7 inch Touch Screen Display.
# The system is password protected & in
compliance with 21CFR Part11 Requirements.
# 8GB large storage memory.
# Quick Test & Analysis in < 3 minutes.
# Detection range - 0.001 - 1.500mg/l (ppm).
# Equipped with Conductivity detector.
to quantify TOC Concentration.
# 7 inch Touch Screen Display.
# The system is password protected & in
compliance with 21CFR Part11 Requirements.
# 8GB large storage memory.
# Quick Test & Analysis in < 3 minutes.
COD Analyzer with Digestor , BOD Analyzer
COD1500
COD Analyzer with Digestor
# Measuring range:0 to 150, 0 to 1500 ppm
# COD Analyzer is water quality analyzer.
# LCD display.
# 2 LED light sources for different COD
# Testing ranges.
Data capacity 200 sets (GLP-compliance).
# 2-point calibration.
# COD Digestor also available.
# Measuring range:0 to 150, 0 to 1500 ppm
# COD Analyzer is water quality analyzer.
# LCD display.
# 2 LED light sources for different COD
# Testing ranges.
Data capacity 200 sets (GLP-compliance).
# 2-point calibration.
# COD Digestor also available.
COD Digestor
BOD4000
BOD Analyzer
# Measuring principle: differential pressure
(manometric).
# BOD value of the current test can be
read at all times.
# Measuring Range - 0 to 4000 mg/l (ppm)
can be measured using different sample
volumes.
# Measuring principle: differential pressure
(manometric).
# BOD value of the current test can be
read at all times.
# Measuring Range - 0 to 4000 mg/l (ppm)
can be measured using different sample
volumes.
Visible Spectrophotometer , Peltier /Sipper System
LMSPV325
Visible Spectrophotometer
# Wavelength Range – 325-1000nm
# Bandwidth – 4nm
# Wavelength Accuracy - ±1nm
# Wavelength setting – Automatic
# Photometric Model – T.A.C.F
# Light Source – Tungsten Lamp
# Wavelength Range – 325-1000nm
# Bandwidth – 4nm
# Wavelength Accuracy - ±1nm
# Wavelength setting – Automatic
# Photometric Model – T.A.C.F
# Light Source – Tungsten Lamp
LMSPV320
Visible Spectrophotometer
# Wave length range - 325-1000nm
# Spectral Bandwidth – 4nm
# Wavelength Accuracy - ±2nm
# Photometric Mode – T.A.C.F
# Output – USB Port & Parallel (Printer)
# Wavelength Setting – Manual
# Light Source – Tungsten Lamp
# Wave length range - 325-1000nm
# Spectral Bandwidth – 4nm
# Wavelength Accuracy - ±2nm
# Photometric Mode – T.A.C.F
# Output – USB Port & Parallel (Printer)
# Wavelength Setting – Manual
# Light Source – Tungsten Lamp
PS1565
Peltier / Sipper System
# Suitable for Spectrophotometers
# It is used to the Control Sample Temperature
# Temperature range - 15°C to 65°C
# Time range - 30sec to 10min.
# Peristaltic pump speed range - 1 to 12
# Suitable for Spectrophotometers
# It is used to the Control Sample Temperature
# Temperature range - 15°C to 65°C
# Time range - 30sec to 10min.
# Peristaltic pump speed range - 1 to 12
Double Beam / Single Beam UV-Vis Spectrophotometer
LMSPUV1900 , 1908 , 1920 , 1928
Double Beam UV-Vis Spectrophotometer
# LMSPUV1900 Bandwidth – 1nm
# LMSPUV1908 -Variable Bandwidth(1/2/4nm)
# Optical System– Double Beam
# Grating 1200lines/mm
Wavelength Range – 190-1100nm
# Wavelength Accuracy - ±0.3nm
# Scanning Speed – Fast, Medium & Low
# Light Source – D2 Lamp & Tungsten Lamp
# LMSPUV1900 Bandwidth – 1nm
# LMSPUV1908 -Variable Bandwidth(1/2/4nm)
# Optical System– Double Beam
# Grating 1200lines/mm
Wavelength Range – 190-1100nm
# Wavelength Accuracy - ±0.3nm
# Scanning Speed – Fast, Medium & Low
# Light Source – D2 Lamp & Tungsten Lamp
LMSPUV1200
Single Beam UV-Vis Spectrophotometer
# Wavelength Range – 190-1100nm
# Bandwidth – 2nm
# Optical System– Single Beam
# Grating 1200 lines/mm
# Wavelength Accuracy - ±0.8nm
# Wavelength Setting – Automatic
# Light Source – D2 Lamp & Tungsten Lamp
# Wavelength Range – 190-1100nm
# Bandwidth – 2nm
# Optical System– Single Beam
# Grating 1200 lines/mm
# Wavelength Accuracy - ±0.8nm
# Wavelength Setting – Automatic
# Light Source – D2 Lamp & Tungsten Lamp
LMSPUV1000B
Single Beam UV-Vis Spectrophotometer
# Optical System – Single beam
# Grating 1200 lines/mm
# Wavelength Range – 190-1000nm
# Bandwidth – 2nm
# Wavelength Accuracy - ±1nm
# Wavelength Repeatability - ±0.5nm
Wavelength Setting – Automatic
# Light Source – D2 lamp & Tungsten Lamp
# Optical System – Single beam
# Grating 1200 lines/mm
# Wavelength Range – 190-1000nm
# Bandwidth – 2nm
# Wavelength Accuracy - ±1nm
# Wavelength Repeatability - ±0.5nm
Wavelength Setting – Automatic
# Light Source – D2 lamp & Tungsten Lamp
Double/ Single Beam UV-Vis Spectrophotometer -Touchscreen
LUV2100T
Double Beam UV-Vis Spectrophotometer Touchscreen
# Wavelength range 190 -1100 nm.
# LUV2000T - Bandwidth-1nm.
# LUV2100T-Variable Bandwidth(1/2/4/5nm).
# Wavelength Accuracy - +0.1nm.
# Display - 10 inches Touch Screen.
# GLP & GMP Standards.
# 21CFR Part 11.
# Memory - 32GB.
# Wavelength range 190 -1100 nm.
# LUV2000T - Bandwidth-1nm.
# LUV2100T-Variable Bandwidth(1/2/4/5nm).
# Wavelength Accuracy - +0.1nm.
# Display - 10 inches Touch Screen.
# GLP & GMP Standards.
# 21CFR Part 11.
# Memory - 32GB.
LUV2000T
Double Beam UV-Vis Spectrophotometer Touchscreen
# Wavelength range 190 -1100 nm.
# LUV2000T - Bandwidth-1nm.
# LUV2100T-Variable Bandwidth(1/2/4/5nm).
# Wavelength Accuracy - +0.1nm.
# Display - 10 inches Touch Screen.
# GLP & GMP Standards.
# 21CFR Part 11.
# Memory - 32GB.
# Wavelength range 190 -1100 nm.
# LUV2000T - Bandwidth-1nm.
# LUV2100T-Variable Bandwidth(1/2/4/5nm).
# Wavelength Accuracy - +0.1nm.
# Display - 10 inches Touch Screen.
# GLP & GMP Standards.
# 21CFR Part 11.
# Memory - 32GB.
LUV1100T
Single Beam UV-Vis Spectrophotometer Touchscreen
# Single Beam UV-Vis. Spectrophotometer.
# Wavelength range 190 -1100 nm.
# Bandwidth - 2 nm.
# Wavelength Accuracy - +0.5 nm.
# Display - 10 inch Touch Screen.
# 21CFR Part 11.
# Memory - 32GB.
# Single Beam UV-Vis. Spectrophotometer.
# Wavelength range 190 -1100 nm.
# Bandwidth - 2 nm.
# Wavelength Accuracy - +0.5 nm.
# Display - 10 inch Touch Screen.
# 21CFR Part 11.
# Memory - 32GB.
Probe Sonicator
PRO660R
Touch screen Probe Sonicator with Remote
# 7" TFT Touch screen with remote control
# In built LED light in sound proof enclosure
# Temperature Meter display on screen.
# Circulating Glass beaker to rotate the sample
# Pulse/Frequency & Time Graph in Wave
formation.
# Ultraviolet Sterilization function.
# Power 6.5 - 650W adjustable.
# With Soundproof Enclosure
# Standard Probe - 6mm
# 7" TFT Touch screen with remote control
# In built LED light in sound proof enclosure
# Temperature Meter display on screen.
# Circulating Glass beaker to rotate the sample
# Pulse/Frequency & Time Graph in Wave
formation.
# Ultraviolet Sterilization function.
# Power 6.5 - 650W adjustable.
# With Soundproof Enclosure
# Standard Probe - 6mm
PRO656 , PRO900 , PRO1200
Touch screen Probe Sonicator
# 7" TFT Touch screen display.
# In built LED light in sound proof enclosure
# Temperature Meter display on screen.
# Circulating Glass beaker to rotate the
sample- Standard Supply.
# Pulse/ Frequency and Time Graph
in Wave formation.
# PRO656 - Power 6.5 - 650W adjustable
# PRO900- Power 9 - 900W adjustable.
# PRO1200- Power 12 - 1200W adjustable.
# With Soundproof Enclosure
# PRO656 & PRO900- Standard Probe- 10mm
# PRO1200 - Standard Probe- 20mm
# 7" TFT Touch screen display.
# In built LED light in sound proof enclosure
# Temperature Meter display on screen.
# Circulating Glass beaker to rotate the
sample- Standard Supply.
# Pulse/ Frequency and Time Graph
in Wave formation.
# PRO656 - Power 6.5 - 650W adjustable
# PRO900- Power 9 - 900W adjustable.
# PRO1200- Power 12 - 1200W adjustable.
# With Soundproof Enclosure
# PRO656 & PRO900- Standard Probe- 10mm
# PRO1200 - Standard Probe- 20mm
PB2 ,3 ,6 ,8 ,10, 12 ,15 ,20 ,22
Probe
Refrigerated Circulating Bath
RCB1020T
Refrigerated Circulating Bath
# Touch screen Display.
# PT100 temperature sensor.
# Folding handles for easy movement.
# PID temperature control system.
# Stainless steel inner tank.
# Waterlevel alarm function.
# Pump flow rate 8L/min.
# Programmable temperature controller.
# Touch screen Display.
# PT100 temperature sensor.
# Folding handles for easy movement.
# PID temperature control system.
# Stainless steel inner tank.
# Waterlevel alarm function.
# Pump flow rate 8L/min.
# Programmable temperature controller.
RCB620T
Refrigerated Circulating Bath
# Touch screen Display, Horizontal Design
# Specialized Model to attach Viscometer on
Top
# PT100 temperature sensor.
# Folding handles for easy movement.
# PID temperature control system.
# Stainless steel inner tank, Overheat
protection.
# Pump flow rate 6L/min.
# Touch screen Display, Horizontal Design
# Specialized Model to attach Viscometer on
Top
# PT100 temperature sensor.
# Folding handles for easy movement.
# PID temperature control system.
# Stainless steel inner tank, Overheat
protection.
# Pump flow rate 6L/min.
Automatic Digital Polarimeter
ADP100CFR
Automatic Digital Polarimeter
# Dual Wavelength - 546nm & 589nm.
# Measuring Range +/- 90° (Optical Rotation)
+/-259°Z (Sugar).
# Compliance with Regulations GMP/ GLP/
FDA 21CFR Part 11.
# Display - 8 inch Colour Touch Screen.
# Temp. Control Mode - Peltier (In-Built).
# Memory - 16GB.
# Dual Wavelength - 546nm & 589nm.
# Measuring Range +/- 90° (Optical Rotation)
+/-259°Z (Sugar).
# Compliance with Regulations GMP/ GLP/
FDA 21CFR Part 11.
# Display - 8 inch Colour Touch Screen.
# Temp. Control Mode - Peltier (In-Built).
# Memory - 16GB.
ADP45
Automatic Digital Polarimeter
# No. of Measuring Mode -4
# Optical Rotation, Specific Rotation,
Sugar, Concentration
# ADP45 - Measuring Range -45° +45°
# 8” Colour Display Datamatrix Touch Screen
# ADP90 Peltier built In
# Length of test tube – 100mm & 200mm
# Interface – USB & RS232C
# No. of Measuring Mode -4
# Optical Rotation, Specific Rotation,
Sugar, Concentration
# ADP45 - Measuring Range -45° +45°
# 8” Colour Display Datamatrix Touch Screen
# ADP90 Peltier built In
# Length of test tube – 100mm & 200mm
# Interface – USB & RS232C
ADP90
Automatic Digital Polarimeter
# No. of Measuring Mode -4
# Optical Rotation, Specific Rotation,
Sugar, Concentration
# ADP45 - Measuring Range -45° +45°
# ADP90 - Measuring Range - 90°+90°Unit - Angle°
# 8” Colour Display Datamatrix Touch Screen
# ADP90 Peltier built In
# Length of test tube – 100mm & 200mm
# Interface – USB & RS232C
# No. of Measuring Mode -4
# Optical Rotation, Specific Rotation,
Sugar, Concentration
# ADP45 - Measuring Range -45° +45°
# ADP90 - Measuring Range - 90°+90°Unit - Angle°
# 8” Colour Display Datamatrix Touch Screen
# ADP90 Peltier built In
# Length of test tube – 100mm & 200mm
# Interface – USB & RS232C
Digital Refractometer , ABBE Refractometer
RFM100CFR
Automatic Digital Refractometer
# In built peltier for Temperature control.
# Window Operating System GMP/ GLP/ FDA 21CFR Part 11.
# 5 Digit Decimal point Precision.
# Display - 8 inch Colour Touch Screen
# High-resolution CCD detection system.
# In built peltier for Temperature control.
# Window Operating System GMP/ GLP/ FDA 21CFR Part 11.
# 5 Digit Decimal point Precision.
# Display - 8 inch Colour Touch Screen
# High-resolution CCD detection system.
RFM950 , RFM970
Automatic Digital Refractometer
# Memory 1024 data
# Refractive index ND – 1.30000-1.70000
# Display – Touch Screen °Brix (BX) – 0 -100%
# Accuracy – Refractive index ND - ±0.0002
# Dissolved Solids °Brix - ±0.1%
# Temperature Display Range – 0 to 50°C
# RFM970 -Thermostatical Control – RT±10°C
# Temperature Control Accuracy - ±0.5°C
# Memory 1024 data
# Refractive index ND – 1.30000-1.70000
# Display – Touch Screen °Brix (BX) – 0 -100%
# Accuracy – Refractive index ND - ±0.0002
# Dissolved Solids °Brix - ±0.1%
# Temperature Display Range – 0 to 50°C
# RFM970 -Thermostatical Control – RT±10°C
# Temperature Control Accuracy - ±0.5°C
LMAR1317T
ABBE Refractometer
# Touch screen Display.
# Measuring Range 1.30000 to 1.72000.
# Fully automatic measuring system.
# Memory- 500 Readings.
# Temp. Range -20°C to +120°C.
# USB Interface, LED bulb
# 5 Digit Decimal Point Precision
# Touch screen Display.
# Measuring Range 1.30000 to 1.72000.
# Fully automatic measuring system.
# Memory- 500 Readings.
# Temp. Range -20°C to +120°C.
# USB Interface, LED bulb
# 5 Digit Decimal Point Precision
Ice Flaker
LMIF200T
Ice Flaker
# Capacity 200kg / 24hrs.
# Touch Screen Display.
# Timer Function, Temperature Function.
# Large Storage capacity- 60kg.
# Refrigerant - R290A.
# Front & Back ventilation design.
# Outer body improved Solid type design.
# Base feet 8 nos .
# Stainless Steel Evaporator.
# Capacity 200kg / 24hrs.
# Touch Screen Display.
# Timer Function, Temperature Function.
# Large Storage capacity- 60kg.
# Refrigerant - R290A.
# Front & Back ventilation design.
# Outer body improved Solid type design.
# Base feet 8 nos .
# Stainless Steel Evaporator.
LMIF30T , 50T
Ice Flaker
# Capacity /24 hrs. - 30kg, 50kg, 100kg.
# Storage Capacity - 7kg, 15kg, 25kg.
# Input Power - 180W, 280W, 420W.
# Touch Screen Display.
# Front & Back ventilation design.
# Stainless Steel Construction.
# Refrigerant - R290A.
# Capacity /24 hrs. - 30kg, 50kg, 100kg.
# Storage Capacity - 7kg, 15kg, 25kg.
# Input Power - 180W, 280W, 420W.
# Touch Screen Display.
# Front & Back ventilation design.
# Stainless Steel Construction.
# Refrigerant - R290A.
LMIF100T
Ice Flaker
# Capacity /24 hrs. - 30kg, 50kg, 100kg.
# Storage Capacity - 7kg, 15kg, 25kg.
# Input Power - 180W, 280W, 420W.
# Touch Screen Display.
# Front & Back ventilation design.
# Stainless Steel Construction.
# Refrigerant - R290A.
# Capacity /24 hrs. - 30kg, 50kg, 100kg.
# Storage Capacity - 7kg, 15kg, 25kg.
# Input Power - 180W, 280W, 420W.
# Touch Screen Display.
# Front & Back ventilation design.
# Stainless Steel Construction.
# Refrigerant - R290A.
Ultrasonic Cleaner
LMUC3D, 6D, 9D, 12D, 25D
Ultrasonic Cleaner
# Degas Function, Blue LED display.
# Normal & Soft power control selectable.
# Heating Temp. - RT. +5 ~ 80℃.
# Quality of handle upgraded for easy grip.
# Extra Power switch ON/OFF on back side
for Safety, Memory -Last test.
# LID & Basket is Standard Supply.
Drainage and cool fan available in 5L to 24L
Viscometer
LMDV60, 100 , 200
Digital Viscometer
# Measuring range –20-2,000,000 / 20-2,000,000 /20-6,000,000 mpa.s
# Speed – 0.3 to 60 /0.3 to 100 / 0.1 to 200
# No of speed – 8 / 18 / 54
# No of standard Spindle – 4
# Display – LCD, Output – RS232C Interface
# Measurement Accuracy - +/-1% (FS)
# Measuring range –20-2,000,000 / 20-2,000,000 /20-6,000,000 mpa.s
# Speed – 0.3 to 60 /0.3 to 100 / 0.1 to 200
# No of speed – 8 / 18 / 54
# No of standard Spindle – 4
# Display – LCD, Output – RS232C Interface
# Measurement Accuracy - +/-1% (FS)
LVA30
Low Viscosity Adaptor
# Spindle range – 1~2K for LMDV60.
# Spindle range – 0.6~6K for range LMDV100
# Spindle range – 0.3~6K for LMDV200
# Low Viscosity adaptor is recommended for
low viscosity sample <20m. pas
# 20 to 30 ml sample is needed for test in
low Viscosity Adaptor (LVA30)
# Spindle Code.L0 is used with low Viscosity
Adaptor
# Spindle range – 1~2K for LMDV60.
# Spindle range – 0.6~6K for range LMDV100
# Spindle range – 0.3~6K for LMDV200
# Low Viscosity adaptor is recommended for
low viscosity sample <20m. pas
# 20 to 30 ml sample is needed for test in
low Viscosity Adaptor (LVA30)
# Spindle Code.L0 is used with low Viscosity
Adaptor
SSA15
Small Sample Adaptor
# Small Sample Adaptor is recommended for
small sample volumes.
# Small Sample Adaptor used for Viscometer
# 10 to 20 ml sample test in small sample
Adaptor.
# Sample temperature can be controlled by
using Refrigerated Circulating bath(Optional)
# Small Sample Adaptor is recommended for
small sample volumes.
# Small Sample Adaptor used for Viscometer
# 10 to 20 ml sample test in small sample
Adaptor.
# Sample temperature can be controlled by
using Refrigerated Circulating bath(Optional)
Dry Bath Incubator , Digital Waterbath
DBI11T
Dry Bath Incubator
# DBI11T - Heating (Touch Screen)
# Temp. Control Accuracy - ±0.5°C
# Temp. Uniformity of Block - ±0.3°C
# Heating Time - ≤15min (25°C up to 100°C)
# Program – Support 5 Multipoint programs
# Standard Block – 35 x 2.0ml
# DBI11T - Heating (Touch Screen)
# Temp. Control Accuracy - ±0.5°C
# Temp. Uniformity of Block - ±0.3°C
# Heating Time - ≤15min (25°C up to 100°C)
# Program – Support 5 Multipoint programs
# Standard Block – 35 x 2.0ml
DBI18 , 20
Dry Bath Incubator
# DBI20 - Heating, Cooling & Stirring
# DBI18 - Heating & Stirring
# Temp. Control Accuracy - ±0.5°C
# Temp. Uniformity of Block - ±0.3°C
# Heating Time - ≤15min (25°C up to 100°C)
# Program – Support 5 Multipoint programs
# Standard Block – 35 x 2.0ml
# DBI20 - Heating, Cooling & Stirring
# DBI18 - Heating & Stirring
# Temp. Control Accuracy - ±0.5°C
# Temp. Uniformity of Block - ±0.3°C
# Heating Time - ≤15min (25°C up to 100°C)
# Program – Support 5 Multipoint programs
# Standard Block – 35 x 2.0ml
LMWB04 , 06
Digital Waterbath
# Column - 2 Rows 4 Holes , 2 Rows 6 Holes
# High Corrosion Resistance
# Temp. Resolution, 0.1 C, Accuracy ±0.5 C
# Power rating 800W / 1200W
# Internal volume (approx.) 12L , 18L
# High Precise Temperature Control.
# Temp. Resolution, 0.1 C, Accuracy ±0.5 C
# Temp. Range RT +5to 99.9° C
# Stainless Steel Tank
# Column - 2 Rows 4 Holes , 2 Rows 6 Holes
# High Corrosion Resistance
# Temp. Resolution, 0.1 C, Accuracy ±0.5 C
# Power rating 800W / 1200W
# Internal volume (approx.) 12L , 18L
# High Precise Temperature Control.
# Temp. Resolution, 0.1 C, Accuracy ±0.5 C
# Temp. Range RT +5to 99.9° C
# Stainless Steel Tank
Vortex Mixer , Bio Chemistry Analyzer , Visual Colarimeter
LMVM60D
Vortex Mixer
# LCD Display with white back light
# Speed Timer (1~99h 59m 59s)
# Aluminum Alloy Base stable body
# Soft silicone foot pads
# Supply with Standard Head
# Operating Mode - 2 Types - Auto run sensor, continuous run for various Mixing application.
# Super shockproof, Bush less Motor.
# LCD Display with white back light
# Speed Timer (1~99h 59m 59s)
# Aluminum Alloy Base stable body
# Soft silicone foot pads
# Supply with Standard Head
# Operating Mode - 2 Types - Auto run sensor, continuous run for various Mixing application.
# Super shockproof, Bush less Motor.
BCA80
Bio Chemistry Analyzer
# 7’’touch screen, 800×480pixels.
# Ambient temperature 10℃-30℃
# Titanium alloy flow cell with small capacity & minimize cross-contamination
# Light source Halogen Lamp 10W/6V,
# Analysis method Kinetics, End point,
Two point, Multi-point.
# Optical System 340-800nm
# 7’’touch screen, 800×480pixels.
# Ambient temperature 10℃-30℃
# Titanium alloy flow cell with small capacity & minimize cross-contamination
# Light source Halogen Lamp 10W/6V,
# Analysis method Kinetics, End point,
Two point, Multi-point.
# Optical System 340-800nm
LMCR80F
Visual Colarimeter
# Measuring Principle Visual, in terms of international colour scale units
# Modes –Transmittance, reflectance
# Measurement Ranges-0.1 -79.9, Red,0.1–79.9
# Yellow, 0.1 – 49.9 Blue, 0.1 -3.9 Neutral
# Viewing System – Fully Adjustable
# Light Source – Incandescent lamp
# Path Length – Up to 180 mm
# Amplification of the magnifiers – 1.9x
# Measuring Principle Visual, in terms of international colour scale units
# Modes –Transmittance, reflectance
# Measurement Ranges-0.1 -79.9, Red,0.1–79.9
# Yellow, 0.1 – 49.9 Blue, 0.1 -3.9 Neutral
# Viewing System – Fully Adjustable
# Light Source – Incandescent lamp
# Path Length – Up to 180 mm
# Amplification of the magnifiers – 1.9x
pH Meter ,Benchtop pH/mV/°C Meter ,Conductivity/TDS/Turbidity Meter
LMPH9
pH Meter - Economic
# Range – 0 to 14.00 pH
# pH Resolution – 0.1pH/0.01 pH
# Accuracy - ±0.01pH
# Calibration Points – up to 3 Points
# pH Buffer Options–USA(pH 4.01,7.00,10.01)
# Temperature Range – 0 to 100°C,
# Temperature
Compensation – Manual
# Memory – up to 25
# Range – 0 to 14.00 pH
# pH Resolution – 0.1pH/0.01 pH
# Accuracy - ±0.01pH
# Calibration Points – up to 3 Points
# pH Buffer Options–USA(pH 4.01,7.00,10.01)
# Temperature Range – 0 to 100°C,
# Temperature
Compensation – Manual
# Memory – up to 25
LMPH10H
pH Meter - 3 points
# pH Range -2.00 to 16.00pH.
# Big Screen & Large LCD Display.
# with white backlight.
# Memory - upto 100 readings.
# USB Interface.
# 0.01pH Resolution.
# 3 points Calibration.
# pH Range -2.00 to 16.00pH.
# Big Screen & Large LCD Display.
# with white backlight.
# Memory - upto 100 readings.
# USB Interface.
# 0.01pH Resolution.
# 3 points Calibration.
LMPH12
pH Meter - 5 points
# Built in real time clock stamps stored data
to meet GLP standards
# pH Range - -2000~20.000pH
# pH Accuracy ±0.002pH
# pH Resolution–0.001,0.01,0.1pH
(Selectable)
# Calibration – upto 5 Points
# pH Buffer Option–USA,NIST,DIN/User Define
# Memory – 500 readings with date & time
# Built in real time clock stamps stored data
to meet GLP standards
# pH Range - -2000~20.000pH
# pH Accuracy ±0.002pH
# pH Resolution–0.001,0.01,0.1pH
(Selectable)
# Calibration – upto 5 Points
# pH Buffer Option–USA,NIST,DIN/User Define
# Memory – 500 readings with date & time
LMPH15
pH Meter with Printer - 5 points
# Built in real time clock stamps stored
data to meet GLP standards
# Range : -2.000 to 20.000 pH
# pH Resolution – 0.001, 0.01 (Selectable)
# Accuracy - ±0.002pH
# Calibration Points – up to 5 Points
# pH Buffer Options–USA,NIST,DIN,
User define
# Password Protection – 4 digits
# Memory – 1000 data sets
# Built in real time clock stamps stored
data to meet GLP standards
# Range : -2.000 to 20.000 pH
# pH Resolution – 0.001, 0.01 (Selectable)
# Accuracy - ±0.002pH
# Calibration Points – up to 5 Points
# pH Buffer Options–USA,NIST,DIN,
User define
# Password Protection – 4 digits
# Memory – 1000 data sets
LMCM20H
Conductivity Meter - 3 points
# Conductivity range - 0 to 200ms/cm
# Big Screen & large LCD Display
# with white backlight.
# Memory- upto 100 readings.
# USB interface
# 0.001 Resolution.
# 3 points Calibration
# Conductivity range - 0 to 200ms/cm
# Big Screen & large LCD Display
# with white backlight.
# Memory- upto 100 readings.
# USB interface
# 0.001 Resolution.
# 3 points Calibration
LMTB200
Turbidity Meter
# Measurement Range – 0~2000 NTU
# Resolution –0.01, 0.1, 1
# Accuracy - ±2% of reading for 0~500 NTU ±3% of reading for 501~2000NTU
# Calibration Points – 2 to 7 points
# Light Source – Infrared –emitting diode
# Memory – Stores up to 200 data sets
# Display – 4.5” TFT display
# Password Protection -Yes
# Measurement Range – 0~2000 NTU
# Resolution –0.01, 0.1, 1
# Accuracy - ±2% of reading for 0~500 NTU ±3% of reading for 501~2000NTU
# Calibration Points – 2 to 7 points
# Light Source – Infrared –emitting diode
# Memory – Stores up to 200 data sets
# Display – 4.5” TFT display
# Password Protection -Yes
Water Quality Multiparameter ,Benchtop ION/pH/mV/°C Meter ,DO Meter
LMMP30
Multiparameter
# Built-in real-time clock stamps stored data
to meets GLP standards
# pH Range -2.000~20.000pH
# Resolution – 0.001, 0.01, 0.1pH, Selectable
# ORP (mV) Range – 0~ ±1999.9mV
# Conductivity Range – 0~200mS/cm
# TDS Range – 0~10ppt
# Salinity Range – 0~80ppt
# Resistivity Range – 0~100M
# Built-in real-time clock stamps stored data
to meets GLP standards
# pH Range -2.000~20.000pH
# Resolution – 0.001, 0.01, 0.1pH, Selectable
# ORP (mV) Range – 0~ ±1999.9mV
# Conductivity Range – 0~200mS/cm
# TDS Range – 0~10ppt
# Salinity Range – 0~80ppt
# Resistivity Range – 0~100M
LMION40
Ion / pH / Meter
# Built –in real-time clock stamps stored data to meets GLP standards
# pH Range - -2.000 ~ 20.000pH
# pH Accuracy - ±0.002pH
# Resolution – 0.001, 0.01, 0.1pH (Selectable)
# Ion Concentration Range 0.001~19999 ppm,mg/L,mol/L
# Ion Concentration Accuracy ±0.5% Full Scale.
# (Monovalent),+1% Full Scale ( Divalent).
# Built –in real-time clock stamps stored data to meets GLP standards
# pH Range - -2.000 ~ 20.000pH
# pH Accuracy - ±0.002pH
# Resolution – 0.001, 0.01, 0.1pH (Selectable)
# Ion Concentration Range 0.001~19999 ppm,mg/L,mol/L
# Ion Concentration Accuracy ±0.5% Full Scale.
# (Monovalent),+1% Full Scale ( Divalent).
LMDO50
Dissolved Oxygen Meter
# DO Range 0.00-2.00mg/L or ppm
# DO Resolution 0.1,0.01ppm. (Selectable)
# DO Accuracy +0.2mg/L or ppm
# Saturation of Oxygen 0.0-200.0%
# Saturation Accuracy +2.0%
# Temperature Range 0.0~50.0°C
# Temperature Accuracy + 0.5°C
# Memory 500 data sets with Date & Time.
# DO Range 0.00-2.00mg/L or ppm
# DO Resolution 0.1,0.01ppm. (Selectable)
# DO Accuracy +0.2mg/L or ppm
# Saturation of Oxygen 0.0-200.0%
# Saturation Accuracy +2.0%
# Temperature Range 0.0~50.0°C
# Temperature Accuracy + 0.5°C
# Memory 500 data sets with Date & Time.
Magnetic Stirrer
LMMS300
Magnetic Stirrer
# Max. Volume – 2000 ml
# Speed – 100 /1250rpm
# Top Plate Size – 135 x135mm
# Plate Material – Steel
# Max. Temp.(Plate Surface) – 300°C
# Timer – 999 minutes
# Max. Volume – 2000 ml
# Speed – 100 /1250rpm
# Top Plate Size – 135 x135mm
# Plate Material – Steel
# Max. Temp.(Plate Surface) – 300°C
# Timer – 999 minutes
LMMS5LC
Ceramic Hotplate Magnetic Stirrer
# Speed – 200-2000 RPM
# Plate Size – 190 x 190mm
# Max. Volume (ml) – 5000ml
# Temp. Controller – PID
Max. Temp. (Plate Surface) - 300°C
# Temp. Accuracy -
±0.5°C(<100°C)±1°C(<300°C)
# Speed – 200-2000 RPM
# Plate Size – 190 x 190mm
# Max. Volume (ml) – 5000ml
# Temp. Controller – PID
Max. Temp. (Plate Surface) - 300°C
# Temp. Accuracy -
±0.5°C(<100°C)±1°C(<300°C)
Online pH/ Conductivity Controller , Gradient Thermal Cycler - PCR
OPH11
Online pH Controller
# to 3 points calibration with auto buffer
recongnization.
# Range -1.00~15.00pH, Resolution–0.01 pH
# pH Buffer Option – USA (4.01/7.00/10.01)
or NIST (4.01/6.86/9.18)
# Low/High Alarm–0.00~14.00pH(Selectable)
# Signal Output 4 ~ 20mA.
# Automatic temperature compensation
# Interface - RS485
# to 3 points calibration with auto buffer
recongnization.
# Range -1.00~15.00pH, Resolution–0.01 pH
# pH Buffer Option – USA (4.01/7.00/10.01)
or NIST (4.01/6.86/9.18)
# Low/High Alarm–0.00~14.00pH(Selectable)
# Signal Output 4 ~ 20mA.
# Automatic temperature compensation
# Interface - RS485
OCM21
Online Conductivity Controller
# 1 to 3 points calibration with auto
recognition of conductivity standards.
# Selectable cell constant, temperature
coefficient and TDS conversion factor.
# Signal Output 4 ~ 20mA
# Automatic temperature compensation
(In built) ensures accurate readings
over the entire range.
# Interface - RS485
# 1 to 3 points calibration with auto
recognition of conductivity standards.
# Selectable cell constant, temperature
coefficient and TDS conversion factor.
# Signal Output 4 ~ 20mA
# Automatic temperature compensation
(In built) ensures accurate readings
over the entire range.
# Interface - RS485
PCR9602G
Gradient Thermal Cycler - PCR
# Capacity – 96 x 0.2ml
# Temperature Range – 0 ~ 100°C
# Max. Heating Rate-5°C/s Cooling Rate-4°C/c
# Uniformity & Accuracy - ≤±0.1°C
# Temperature Control – Block/Tube
# Gradient Temp. Range – 30 ~ 100°C
# Number Of Programs–10000 +(USB FLASH)
# Max. No. of Step – 30,
# Max. No. of Cycl–99
# LCD Display – Touch Screen, TFT
# Capacity – 96 x 0.2ml
# Temperature Range – 0 ~ 100°C
# Max. Heating Rate-5°C/s Cooling Rate-4°C/c
# Uniformity & Accuracy - ≤±0.1°C
# Temperature Control – Block/Tube
# Gradient Temp. Range – 30 ~ 100°C
# Number Of Programs–10000 +(USB FLASH)
# Max. No. of Step – 30,
# Max. No. of Cycl–99
# LCD Display – Touch Screen, TFT
ISE's , Conductivity Cell , Electrodes
ISE62
Nitrate Combination Electrode
# Limits (ppm) – 6200 ppm to 6.2 ppm
# Temperature Range – 5 to 60°C
# Slope -54 to 60 mV
# Cable Length – 1 Meter
# Connector – BNC
# Accessories – Nitrate standard solution
# Limits (ppm) – 6200 ppm to 6.2 ppm
# Temperature Range – 5 to 60°C
# Slope -54 to 60 mV
# Cable Length – 1 Meter
# Connector – BNC
# Accessories – Nitrate standard solution
ISE19
Fluoride Combination Electorde
# Concentration range – 10-1M to 10-5M
# Limits (ppm) – 1900 ppm to 0.2 ppm
# Temperature Range – 5 to 60°C
# Slope -54 to -60 mV
# Cable Length – 1 Meter
# Connector – BNC
# Accessories – Fluoride standard solution
& TISAB (500ml),IFS (30ml)
# Concentration range – 10-1M to 10-5M
# Limits (ppm) – 1900 ppm to 0.2 ppm
# Temperature Range – 5 to 60°C
# Slope -54 to -60 mV
# Cable Length – 1 Meter
# Connector – BNC
# Accessories – Fluoride standard solution
& TISAB (500ml),IFS (30ml)
CC1 , CC2, CC3
Conductivity Cell
# Cell Constant 1K / 0.1K / 10K
# Cell Constant Accuracy 1±0.2/0.1±0.02/10±2
# Measuring Range:
1K-0.01ms/cm to 10ms/cm
0.1K-0.1μs/cm to 100μs/cm
10K-0.1ms/cm to 200ms/cm
# Material Platinum Foils, Glass Body
# Electrode Length 155mm
# Cable length 1 meter with Electrode
# Cell Constant 1K / 0.1K / 10K
# Cell Constant Accuracy 1±0.2/0.1±0.02/10±2
# Measuring Range:
1K-0.01ms/cm to 10ms/cm
0.1K-0.1μs/cm to 100μs/cm
10K-0.1ms/cm to 200ms/cm
# Material Platinum Foils, Glass Body
# Electrode Length 155mm
# Cable length 1 meter with Electrode
PE6
Online pH Electrode
PE6 Online pH Electrode is designed for the measurement of the pH and temperature in aqueous solution and is suitable for continuous use in process application.
PE6 Online pH Electrode is designed for the measurement of the pH and temperature in aqueous solution and is suitable for continuous use in process application.
ER1
pH Electrode - Plastic
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : Fiber.
# Application - General purpose, School college, Lab use, etc.
# www.labman.net.in
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : Fiber.
# Application - General purpose, School college, Lab use, etc.
# www.labman.net.in
ER2
pH Electrode - Plastic
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : Fiber.
# Plastic Type .
# Application - Waste Solution, not suitable for Strong Acid / Alkaline Solution Measurement.
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : Fiber.
# Plastic Type .
# Application - Waste Solution, not suitable for Strong Acid / Alkaline Solution Measurement.
ER3
pH Electrode - Plastic
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : PTFE Ring.
# Plastic Type.
# Application - High/Low Ionic.
Concentration samples like rain water, Drinking water.
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : PTFE Ring.
# Plastic Type.
# Application - High/Low Ionic.
Concentration samples like rain water, Drinking water.
ER4
pH Electrode - Plastic
# pH Range : 2 - 12.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : PTFE Ring.
# Plastic Type - Flat Surface
# Application - Food, Cheese, Paper, Skin, Meat, Butter, etc.
# pH Range : 2 - 12.00pH.
# Temp.range : 5°C to 60°C.
# Liquid Junction Type : PTFE Ring.
# Plastic Type - Flat Surface
# Application - Food, Cheese, Paper, Skin, Meat, Butter, etc.
ER5
pH Electrode - Glass
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 90°C.
# Liquid Junction Type : Ceramic.
# Glass type .
# Application - Strong Acid Alkaline, Organic Solution Measurement.
# pH Range : 0 - 14.00pH.
# Temp.range : 5°C to 90°C.
# Liquid Junction Type : Ceramic.
# Glass type .
# Application - Strong Acid Alkaline, Organic Solution Measurement.
ER6
pH Electrode - Glass
# pH Range : 2 - 12.00pH.
# Temp.range : 5°C to 90°C.
# Liquid Junction Type : Ceramic.
# Glass type .
# Application - Low Ionic Strength. Measurement Solution, like high pure water.
# pH Range : 2 - 12.00pH.
# Temp.range : 5°C to 90°C.
# Liquid Junction Type : Ceramic.
# Glass type .
# Application - Low Ionic Strength. Measurement Solution, like high pure water.
ER7
ORP (Redox) Electrode - Plastic
# Temp.range : 5°C to 60°C.
# Sensor Type : Pt Pin.
# Plastic Type
# Millivolt range(Redox) +1000mV.
Application - General Application of ORP (Redox) Measurements.
# Temp.range : 5°C to 60°C.
# Sensor Type : Pt Pin.
# Plastic Type
# Millivolt range(Redox) +1000mV.
Application - General Application of ORP (Redox) Measurements.
ER8
ORP (Redox) Electrode - Glass
# Redox Potential Measurements.
# Temp.range : 5°C to 90°C.
# Sensor Type : Pt Ring.
# Millivolt range(Redox) +1000mV.
# Glass Type
# Application - High temperature
Redox Potential Measurements
# Redox Potential Measurements.
# Temp.range : 5°C to 90°C.
# Sensor Type : Pt Ring.
# Millivolt range(Redox) +1000mV.
# Glass Type
# Application - High temperature
Redox Potential Measurements